Q series
Output up to 10kV; 0.5W


- Ultra-Miniature Case Size
- Proportional Input/Output
- Optional Control Pin
- Input to Output Galvanic Isolation
- Low Input/Output Coupling Capacitance
- Low Leakage Current
- Short Circuit Protection, 1 Minute Minimum
- No Minimum Load Required
- No External Components Required
- Four Standard Input Voltage Ranges
- Designed to meet UL 94V0
- MTBF >3,000,000 hours, per Belcore TR 332
The Q Series is a broad line of ultra-miniature, high reliability HV DC/DC converters supplying up to 5,000 V in only 0.125 cubic inches and up to 10,000 V in only 0.614 cubic inches. These component-sized converters are ideal for applications requiring minimal size and weight.
The output is directly proportional to the input voltage and is linear from <0.7 V input to maximum input voltage, allowing for an adjustable output voltage. Output is load dependent. Isolation is ±500 V bias on output return. A control pin option allows full control of the output via a high impedance input, ideal for error-amplifier control in closed-loop systems.
No external components or minimum load are required. The output ripple is extremely low for this package size. Light weight and wide temperature range make these units ideal for portable, battery-powered equipment. Many models feature a center-tap option, which creates both a positive and a negative output from one miniature, low cost unit. An alternate pin pattern is available for users wishing to upgrade without modifying their board design.
Applications:
- Avalanche Photodiodes
- Photomultiplier Tubes
- Light Sources
- Piezo Devices
- Sustaining Ion Pumps
- Electrophoresis
- Printers, Igniters
- Capacitor Charging
Options:
- C - Control Pin - up to 5 kV
- CT - Output Center Tap -
up to 900 V - R - RoHS Compliant
- S - External Copper Shield
- T - Extended Operating
Temperature -
Q Series up to 5 kV
Specifications:
- Input Voltage: 0-5 VDC (all models),
0-12 VDC, 0-15 VDC, 0-24 VDC (models up to 3 kV) - Turn-On Voltage: < 0.7 VDC
- Isolation: < ±500 V bias on output return
- Output Voltage Tolerance: +5%/-10%
at full load, max. output voltage - Input/Output Coupling Capacitance: < 50 pF typ.
- Input/Output Leakage Current: < 250 nA typ.
- Ripple: 1%p-p max.
- Control Pin Voltage: 0 to max. input voltage
- Dimensions (LxWxH):
Q01 to Q50: 12.7 x 12.7 x 12.7 mm3
Q60 to Q101: 21.6 x 21.6 x 21.6 mm3
Floating Output Models (Center Tap Option Available)
| Output Voltage [VDC] | Model | Max. Output Current *1 [mA] |
|---|---|---|
| 0 - 100 | Q01-*2 | 5.000 |
| 0 - 150 | Q015-*2 | 3.333 |
| 0 - 200 | Q02-*2 | 2.500 |
| 0 - 250 | Q025-*2 | 2.000 |
| 0 - 300 | Q03-*2 | 1.667 |
| 0 - 350 | Q035-*2 | 1.429 |
| 0 - 400 | Q04-*2 | 1.250 |
| 0 - 450 | Q045-*2 | 1.111 |
| 0 - 500 | Q05-*2 | 1.000 |
| 0 - 600 | Q06-*2 | 0.833 |
| 0 - 700 | Q07-*2 | 0.714 |
| 0 - 800 | Q08-*2 | 0.625 |
| 0 - 900 | Q09-*2 | 0.556 |
Fixed Polarity Output Models
| Output Voltage [VDC] | Positive Output Model | Negative Output Model | Max. Output Current *1 [mA] |
|---|---|---|---|
| 0 - 1000 | Q10-*2 | Q10N-*2 | 0.500 |
| 0 - 1200 | Q12-*2 | Q12N-*2 | 0.417 |
| 0 - 1500 | Q15-*2 | Q15N-*2 | 0.333 |
| 0 - 2000 | Q20-*2 | Q20N-*2 | 0.250 |
| 0 - 2500 | Q25-*2 | Q25N-*2 | 0.200 |
| 0 - 3000 | Q30-*2 | Q30N-*2 | 0.167 |
| 0 - 4000 | Q40-5 | Q40N-5 | 0.125 |
| 0 - 5000 | Q50-5 | Q50N-5 | 0.100 |
| 0 - 6000 | Q60-5 | Q60N-5 | 0.083 |
| 0 - 8000 | Q80-5 | Q80N-5 | 0.063 |
| 0 - 10000 | Q101-5 | Q101N-5 | 0.050 |
*1 - At maximum rated output voltage
*2 - Input voltage range designator: "5", "12", "15" or "24" for 0-5 VDC, 0-12 VDC, 0-15 VDC or 0-24 VDC respectively; available for models up to 3kV - eg. Q30N-12
Disclaimer
Bei den hier angegebenen Informationen handelt es sich um technische Daten, nicht um zugesicherte Produkteigenschaften. Sie wurden sorgfältig geprüft; für mögliche Fehler wird jedoch keine Gewähr übernommen. Der Anwender muss durch geeignete Tests sicherstellen, dass die Produkte für seine Anwendung hinsichtlich Sicherheit und technischer Verwendung geeignet sind. hivolt.de GmbH & Co. KG haftet nicht für mögliche Folgen, die sich aus der Verwendung der angebotenen Produkte ergeben.
Sicherheitshinweis
Installation und Inspektion von sowie der Umgang mit Hochspannung erzeugenden und übertragenden Komponenten dürfen nur von entsprechend qualifiziertem und geschultem Personal vorgenommen werden. Die einschlägigen Vorschriften und Sicherheitsrichtlinien sind stets einzuhalten. Unsachgemäßer Umgang mit Hochspannung kann Tod, schwere Personenschäden und Sachschäden verursachen!