G series
Output up to 6kV 1.5W

Applications:
- Non-impact Printers, Sustaining Ion Pumps
- Piezo Devices, Vacuum Gauges
- Photomultiplier Tubes
- Spectrometry, Electrostatic Chucks
- Lamp Ignition and Drive, Displays
Features:
- Low Ripple, Miniature Case Size
- Low EMI/RFI Sinewave Oscillator
- Proportional Input/Output
- User-Selectable Output Polarity
- Short Circuit Protection
- Low Cost / High Performance
- Input/Output Isolation (Floating Output)
- Center Tap Option
A line of miniature, versatile component level building blocks with low ripple and low EMI/RFI.
The output voltage is directly proportional to the input voltage.
The isolated output allows for user selectable output polarity. An optional output center tap provides, when grounded, both positive and negative outputs.
Typical applications include: non-impact printers, sustaining ion pumps, piezo devices, vacuum, photomultiplier tubes, spectrometry etc.
| Model | Output *3 Voltage | Output *5 Current | Input Voltage | Input *2 Current (No Load) | Input *2 Current (Full Load) | Ripple |
|---|---|---|---|---|---|---|
| G01 | 0 - 0.1kV | 15mA | 0 - 12V | <100mA | <250mA | <1.75% |
| G02 | 0 - 0.2kV | 7.5mA | 0 - 12V | <100mA | <250mA | <0.75% |
| G03 | 0 - 0.3kV | 5mA | 0 - 12V | <100mA | <250mA | <0.75% |
| G05 | 0 - 0.5kV | 3mA | 0 - 12V | <100mA | <250mA | <0.02% |
| G06 | 0 - 0.6kV | 2.5mA | 0 - 12V | <100mA | <250mA | <0.1% |
| G10 | 0 - 1kV | 1.5mA | 0 - 12V | <100mA | <250mA | <0.1% |
| G12 | 0 - 1.2kV | 1.25mA | 0 - 12V | <150mA | <275mA | <0.1% |
| G15 | 0 - 1.5kV | 1mA | 0 - 12V | <125mA | <275mA | <0.5% |
| G20 | 0 - 2kV | 0.75mA | 0 - 12V | <165mA | <275mA | <0.5% |
| G25 | 0 - 2.5kV | 0.6mA | 0 - 12V | <125mA | <275mA | <1.0% |
| G30 | 0 - 3kV | 0.5mA | 0 - 12V | <125mA | <300mA | <2.0% |
| G40 *1 | 0 - 4kV | 0.37mA | 0 - 12V | <125mA | <300mA | <1.0% |
| G50 *1 | 0 - 5kV | 0.3mA | 0 - 12V | <125mA | <300mA | <2.0% |
| G60 *1 | 0 - 6kV | 0.25mA | 0 - 12V | <125mA | <300mA | <2.0% |
| (col7) | ||||||
| GPMT | 0 - 1.25kV | 0.35mA | 0 - 12V | <35mA | <75mA | 0.05% |
*1 Caution: Models G40, G50 & G60 do not have internal bleeder resistors on the output.
Provisions must be made externally to discharge the output capacitors if this feature is desired.
*2 At maximum rated output voltage.
*3 Output Voltage is load dependent. Under light or no load conditions, reduce input
voltage so maximum rated output voltage is not exceeded.
*4 Specifications after 30 minutes warm-up, full load, at 25°C unless otherwise noted.
*5 The rated output current is available at full output voltage and must be derated
proportionally as the input voltage decreases.
For example: a 500V, 1.5W unit, rated at 3mA at 500V will provide 1.5mA at 250V out.
|
| ||||||||||||||||||||||||||||||||||||||||||
Disclaimer
Bei den hier angegebenen Informationen handelt es sich um technische Daten, nicht um zugesicherte Produkteigenschaften. Sie wurden sorgfältig geprüft; für mögliche Fehler wird jedoch keine Gewähr übernommen. Der Anwender muss durch geeignete Tests sicherstellen, dass die Produkte für seine Anwendung hinsichtlich Sicherheit und technischer Verwendung geeignet sind. hivolt.de GmbH & Co. KG haftet nicht für mögliche Folgen, die sich aus der Verwendung der angebotenen Produkte ergeben.
Sicherheitshinweis
Installation und Inspektion von sowie der Umgang mit Hochspannung erzeugenden und übertragenden Komponenten dürfen nur von entsprechend qualifiziertem und geschultem Personal vorgenommen werden. Die einschlägigen Vorschriften und Sicherheitsrichtlinien sind stets einzuhalten. Unsachgemäßer Umgang mit Hochspannung kann Tod, schwere Personenschäden und Sachschäden verursachen!