Skip navigation

CA series

Output up to 2kV 1W

The CA Series of high performance,precision regulated, high voltage power supplies offers improved performance and added features. Improvements in stability and ripple, along with an on-board precision reference, voltage monitor and increased protection enable these modules to replace much larger, more expensive power supplies in many applications.

Each model is programmed from 0 to 100% of rated output via a 0 to +5VDC compatible high impedance programming *6 input.

A voltage monitor is provided and is internally buffered to provide a low impedance (up to 1mA) signal to external circuitry. The precision on-board reference can be used in conjunction with an external potentiometer or voltage divider to program a high voltage output.

Each unit has an accessible potentiometer allowing for individual calibration after installation. A quasi sine wave oscillator, internal transformer shielding and an isolated steel case reduce EMI/RFI radiation to very low levels. Suitable for photomultiplier tubes, avalanche photodiodes, precision EO lenses, piezo devices and other applications requiring precision, low noise high voltage in a miniature, PCB mountable, cost effective package.

Features:

  • Very low ripple
  • Precision regulated
  • Miniature shielded case
  • 0 to 100% programmable
  • Voltage monitor output
  • High stability
  • Wide input voltage range
  • Arc, Short Circuit Protected
       12V Input models: indefinite
        5V Input models: short duration, up to 1 minute
  • UL94-V0 Compliant Epoxy

Specifications *1:

   Input Voltage:11.5 VDC to 15.5 VDC
4.75VDC to 5.25 VDC for 5V Input Power option
   Input Current:<80mA no load /<220mA full load,
<65mA no load /<420mA full load for 5V Input Power option
   Remote control
   voltage (Vcon-in):
0 to 5 VDC , <150 µA
0 to 2.048 VDC , <150 µA for 5V Input Power option
   Voltage monitor:0 to 5 V = 0 to 100% VOUT *2
0 to 2.048 V = 0 to 100% VOUT for 5V Input Power option *2
   Reference output:5.0 V ±1% , up to 1mA,
2.048 V ±1% , up to 1mA for 5V Input Power option
   Stability:<0.005%/hr *3
   Linearity:<0.5% (15% to 100% VOUT) *3
   Set Point Accuracy:1% *3
   Trim:1% *3
   Temp. coefficient:<25ppm/°C *3
   Operating temp.:-10°C to +50°C   (-55°C to +70°C option available)
   Storage temp.:-25°C to +95°C
   Thermal Shock Limit:1°C/10s
  
MODELOUTPUT VOLTAGEOUTPUT CURRENT *5REGULATION *3RIPPLE *3
(Full load p-p)
LINELOAD
CA02P0 to +200V0 to 5mA<0.01%<0.05%<0.01%
CA02P-50 to +200V0 to 5mA<0.01%<0.01%<0.01%
CA02N0 to -200V0 to 5mA<0.01%<0.05%<0.01%
CA02N-50 to -200V0 to 5mA<0.003%<0.005%<0.01%
CA05P0 to +500V0 to 2mA<0.01%<0.01%<0.01%
CA05P-50 to +500V0 to 2mA<0.002%<0.003%<0.005%
CA05N0 to -500V0 to 2mA<0.01%<0.01%<0.01%
CA05N-50 to -500V0 to 2mA<0.002%<0.005%<0.005%
CA10P0 to +1000V0 to 1mA<0.001%<0.005%<0.001%
CA10P-50 to +1000V0 to 1mA<0.001%<0.005%<0.001%
CA10N0 to -1000V0 to 1mA<0.001%<0.005%<0.001%
CA10N-50 to -1000V0 to 1mA<0.001%<0.005%<0.001%
CA12P0 to +1200V0 to 0.8mA<0.001%<0.005%<0.0005%
CA12P-50 to +1200V0 to 0.8mA<0.001%<0.005%<0.001%
CA12N0 to -1200V0 to 0.8mA<0.001%<0.005%<0.0005%
CA12N-50 to -1200V0 to 0.8mA<0.001%<0.005%<0.001%
CA20P0 to +2000V0 to 0.5mA<0.01%<0.01%<0.001%
CA20P-50 to +2000V0 to 0.5mA<0.003%<0.005%<0.001%
CA20N0 to -2000V0 to 0.5mA<0.01%<0.01%<0.001%
CA20N-50 to -2000V0 to 0.5mA<0.001%<0.001%<0.001%

* Notes:

  1. Specifications after 1 hour warm-up, full load, +25°C unless otherwise noted.
  2. On negative output models, voltage monitor output is a buffered representation of the programming voltage.
  3. Typical performance.
  4. All grounds internally connected, except case.
  5. Maximum rated output current is typically available from 100% max output voltage to 50% max output voltage, and is derated below 50% max output voltage.
  6. 5V Input Power option, programming and voltage monitor are 0 to +2.048V.

Options:

-R      RoHS Compliant
-T      Extended Operating Temperature

Disclaimer

The information given here is technical data, not assured product characteristics. It has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. The user has to ensure by adequate tests that the product is suitable for his application regarding safety and technical aspects.
hivolt.de GmbH & Co. KG does not assume any liability arising out of the application or use of any product described.

Safety Advice

Design, installation and inspection of machinery and devices carrying high voltage require accordingly trained and qualified personnel. Appropriate safety rules and directives must be complied with.
Improper handling of high voltage can mean severe injuries or death and may cause serious collateral damage!