Skip navigation

AWG Table

SIZE
[AWG]

[#]

[AWG]
AREA
[mm²]
DIA
[mm]
44solid0.00200.050
43solid0.00250.056
42solid0.00320.063
41solid0.00400.071
40solid0.00500.080
39solid0.00630.090
38solid0.00800.10
37solid0.0100.11
36solid0.0130.13
367440.0140.15
35solid0.0160.14
34solid0.0200.16
347420.0220.19
33solid0.0250.18
32solid0.0320.20
327400.0350.24
3219440.0380.24
31solid0.0400.23
30solid0.0510.25
307380.0560.30
3019420.0600.31
29solid0.0640.29
28solid0.0810.32
287360.0890.38
2819400.0950.39
27solid0.100.36
26solid0.130.40
267340.140.48
2610360.130.48
2619380.150.49
25solid0.160.45
24solid0.210.51
247320.220.61
2410340.200.61
2419360.240.62
2441400.210.58
23solid0.260.57
22solid0.330.64
227300.360.76
2219340.380.78
2226360.330.74
21solid0.410.72
20solid0.520.81
207280.570.96
2010300.510.97
2019320.610.98
2026340.520.93
2041360.520.92
19solid0.650.91
SIZE
[AWG]

[#]

[AWG]
AREA
[mm²]
DIA
[mm]
18solid0.821.02
187260.901.21
1816300.821.18
1819300.971.24
1841340.831.16
1865360.821.15
17solid1.01.15
16solid1.31.29
167241.41.47
1619291.21.45
1626301.31.52
1665341.31.52
16105361.31.44
15solid1.71.45
14solid2.11.63
147222.31.93
1419271.91.80
1441302.11.96
14105342.11.82
13solid2.61.83
12solid3.32.05
127203.62.44
1219253.12.29
1237283.02.17
1261293.92.48
1265303.32.31
12165343.32.27
11solid4.22.30
10solid5.32.59
1037264.82.74
1049275.02.84
10105305.43.30
9solid6.62.91
8solid8.43.26
819217.83.51
849258.03.59
8133298.54.22
8168308.64.42
8665368.43.53
7solid10.53.66
6solid13.34.12
61332713.65.33
62663013.55.18
5solid16.84.62
4solid21.25.19
44203021.46.53
3solid26.75.83
2solid33.66.54
26653033.98.59
1solid42.47.35
0solid53.58.25

The diameters of stranded wires given in this table are approximate values. The actual diameter may vary depending on the build-up of the particular cable.

Disclaimer

The information given here is technical data, not assured product characteristics. It has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. The user has to ensure by adequate tests that the product is suitable for his application regarding safety and technical aspects.
hivolt.de GmbH & Co. KG does not assume any liability arising out of the application or use of any product described.

Safety Advice

Design, installation and inspection of machinery and devices carrying high voltage require accordingly trained and qualified personnel. Appropriate safety rules and directives must be complied with.
Improper handling of high voltage can mean severe injuries or death and may cause serious collateral damage!